Grazing Incident X-ray Diffraction Analysis (GIXRD)

High Resolution X-ray Diffraction Analysis (HRXRD)

Single Crystal X-ray Diffraction Analysis (SCXRD)
Small Angle X-ray Scattering & Wide-Angle X-ray Scattering (SAXS/WAXS)
Small angle X-ray scattering (SAXS) is a technique used to investigate the structure of particle systems in order to quantify the size distribution and shape of the particles. This method involves x-ray scattering at very low angles (0-10° in 2q) capturing particle sizes in the range of 1-100 nm. X-ray scattering at wider angles can also be collected at >10° in 2q capturing smaller dimensions of <1nm. This corresponds to wide angle X-ray scattering (WAXS) and it probes the crystalline structure of the particle. The WAXS data carries the same information as the data collected using normal XRD analysis.
The SAXS-WAXS technique can also be applied in reflection mode and this is commonly called as Grazing Incidence (GI) SAXS-WAXS. GISAXS/GIWAXS is use to characterise the structural assembly of nanoparticles and crystals on a surface.
SAXS is applied to a broad range of materials, including colloids of all types of metals, cement, oil, polymers, proteins, foods and pharmaceuticals found in academic research and quality control in industry.


XRF Bruker S8 Tiger
What Is XRF and how is it used?
XRF machines are used to gain bulk elemental composition in a non-destructive way.
With detection limits down to ppm and the ability to analyse from Boron to Uranium, XRF offers an alternative to smaller volume, destructive elemental analysis like ICP-MS or EPMA.
What samples can we run?
We can run solids or liquids.
- For solids, we can run them as loose powders, pressed pellets or fused beads. A typical run would use around 10g of material to form a pressed pellet.
However, if sample amount is limited, we can run smaller volumes as pressed pellets (made for instance using a press) or as loose powders.
If you require usage with assistance, then we can only do loose powders or pressed pellets currently. - For liquids, we can run them as long as they don’t react with prolene, polyester or Mylar.
This will be at FACTS discretion however, due to the large problems that arise if the liquid leaks.
Detection method: wavelength-dispersive
Source: rhodium tube 4kW
Analyser crystals: LIF 200; PET; XS-55; XS-GE
Sample types possible: pressed pellet cups; liquid samples
Multiple-sample automatic changer
- Elemental composition analysis (WDX) for various sample types

X-ray reflectivity (XRR)

Crystal orientation mapping

High-flux X-ray source
X-ray Fluorescence Spectroscopy (XRF)
XRF machines are used to determine bulk elemental composition in a non-destructive way.
With detection limits down to ppm and the ability to analyse from Boron to Uranium, XRF offers an alternative to smaller volume, destructive elemental analysis like ICP-MS or EPMA.
in-situ X-ray diffraction/scattering analysis
Some of our X-ray instruments come with different stages that allow for in-situ X-ray scattering experiments.
If you have some in-situ or in-operando experiments that requires a DIY or a different set-up we are more than happy to discuss the possibilities. What we care most is the quality of data you can collect consistent with the safe operation of the instrument.
Anton Paar DHS 1100 heating stage
Heating range: RT to 1100 °C
Used in Bruker D8 Discover

Linkam heating-cooling stage
range: -150°C to 350°C
transmission samples: powder, liquid or gel
reflection samples: thin film, plate
used in Xenocs Nanoinxider for SAXS/WAXS and GISAXS/GIWAXS
Electrochemical cell
for use in Rigaku Smartlab